dc.description.abstract850 thousand workers per year spread across the 32 states, of which Puebla contributes with 465 106, developing, in a high percentage, the verification of new parts as part of the manufacture process. This activity is supported by the use of devices known as fixtures, whose equipment and tool forces operators to lift loads between 10 and 50 kilograms by performing manual operations to hold parts, presenting pain at the lumbar level, therefore, it is essential to measure the risks of back injuries in the study population. The objective was to identify and measure the risks of back injuries in the study population. Materials and Methods: The inspection process is analyzed by identifying the potential risk factors. Ergonomic methodologies and instruments are used, such as Quick Exposure Check (qec), the National Institute for Occupational Safety and Health (niosh) equation, the reba (Rapid Entire Body Assessment) method, Ovako’s Work Posture Analysis System (owas), among others. Results: The qec method shows that trunk/back and wrist/hand are the most sensitive parts to risk exposure, indicating that 18 % of the postures are rated 4 in the level of risk, with the back rotated and bent in over 32 % of time. The weight of the operation exceeds 20 kilograms in 71.4 %. Conclusion: Four ergonomic techniques are used to assess the risk of injury, the inspection process of manufactured parts is analyzed.es_MX
dc.description.urihttps://revistas.urosario.edu.co/index.php/revsalud/article/.../7131es_MX
dc.language.isoenes_MX
dc.relation.ispartofProducto de investigación IITes_MX
dc.relation.ispartofInstituto de Ingeniería y Tecnologíaes_MX
dc.rightsAtribución-NoComercial-SinDerivadas 2.5 México*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/2.5/mx/*
dc.subjectErgonomics, risk control, quality inspection.es_MX
dc.subject.otherinfo:eu-repo/classification/cti/5es_MX
dc.titleMeasuring Back Injury Risk in Mexican Workers of an Automotive Companyes_MX
dc.typeArtículoes_MX
dcterms.thumbnailhttp://ri.uacj.mx/vufind/thumbnails/rupiiit.pnges_MX
dcrupi.institutoInstituto de Ingeniería y Tecnologíaes_MX
dcrupi.cosechableSies_MX
dcrupi.norevista2es_MX
dcrupi.volumen17es_MX
dcrupi.nopagina175-187es_MX
dc.identifier.doiDoi: http://dx.doi.org/10.12804/revistas.urosario.edu.co/revsalud/a.7921es_MX
dc.contributor.coauthorUribe, Luis alberto
dc.contributor.coauthorGarcía, José
dc.contributor.coauthorEscobedo, Maria Teresa
dc.journal.titleRevista Ciencias de la Saludes_MX
dc.lgacProcesos Industrialeses_MX
dc.cuerpoacademicoPlaneación Tecnológica y Diseño Ergonómicoes_MX


Archivos en el ítem

Thumbnail
Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Atribución-NoComercial-SinDerivadas 2.5 México
Excepto si se señala otra cosa, la licencia del ítem se describe como Atribución-NoComercial-SinDerivadas 2.5 México

Av. Plutarco Elías Calles #1210 • Fovissste Chamizal
Ciudad Juárez, Chihuahua, México • C.P. 32310 • Tel. (+52) 688 – 2100 al 09