Mostrar el registro sencillo del ítem

dc.date.accessioned2022-09-08T19:07:47Z
dc.date.available2022-09-08T19:07:47Z
dc.date.issued2022-05-31es_MX
dc.identifier.urihttp://cathi.uacj.mx/20.500.11961/22199
dc.description.abstractDiabetic foot ulcers (DFUs) are an ominous consequence of diabetic foot. To develop a multidimensional lesion warning device, several variables must be considered, among which vascular parameters. To minimize the number of sensors, we investigate the use of standard flexible force sensing resistors (FSRs), FSR402 and FSR406, to detect not only plantar pressure but also bioimpedance plethysmography. Since FSRs include conductive electrodes covered by polymer film, the interface with the subject can be considered a capacitive electrode. We present a special impedance plethysmography (IPG) circuit to inject current using FSRs and measuring the resulting voltage from other FSRs contacts. IPG simulations with two modeled FSRs, two contacts each, were not successful, but using four FSRs, one capacitive contact each, shows a precision within 4% of the expected FSR resistor value. The IPG system was verified with simultaneously matching ECG-lead I, Ag–AgCl, and capacitive electrode signals alongside power spectra. For the first time, four sole pressure sensors are used also as bioimpedance electrodes to detect cardiac activity with standard components at frequencies up to 50 kHz and simulated as well as experimentally verified on one healthy subject.es_MX
dc.description.urihttps://ieeexplore.ieee.org/document/9785883es_MX
dc.language.isospaes_MX
dc.relation.ispartofProducto de investigación IITes_MX
dc.relation.ispartofInstituto de Ingeniería y Tecnologíaes_MX
dc.rightsAtribución-NoComercial-SinDerivadas 2.5 México*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/2.5/mx/*
dc.subject.otherinfo:eu-repo/classification/cti/7es_MX
dc.titleForce Sensing Resistors Used as Plantar Impedance Plethysmography Electrodeses_MX
dc.typeArtículoes_MX
dcterms.thumbnailhttp://ri.uacj.mx/vufind/thumbnails/rupiiit.pnges_MX
dcrupi.institutoInstituto de Ingeniería y Tecnologíaes_MX
dcrupi.cosechableSies_MX
dcrupi.volumen71es_MX
dcrupi.nopagina1-8es_MX
dc.identifier.doi10.1109/TIM.2022.3178961es_MX
dc.contributor.coauthorGonzalez Landaeta, Rafael Eliecer
dc.journal.titleIEEE Transactions on Instrumentation and Measurementes_MX
dc.contributor.authorexternoMorales, Isabel
dc.contributor.coauthorexternoSimini, Franco
dcrupi.pronacesNingunoes_MX


Archivos en el ítem

Thumbnail
Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Atribución-NoComercial-SinDerivadas 2.5 México
Excepto si se señala otra cosa, la licencia del ítem se describe como Atribución-NoComercial-SinDerivadas 2.5 México

Av. Plutarco Elías Calles #1210 • Fovissste Chamizal
Ciudad Juárez, Chihuahua, México • C.P. 32310 • Tel. (+52) 688 – 2100 al 09