dc.description.abstractThe accelerated aging process is incorporated into the design and development of intravascular catheters to assess their reliability assuring that this medical device is safe and effective for the intended use during their shelf life. The accelerated aging process is based on a common approach that assumes that the rate of aging increases by a factor of , where is the temperature increment. However, with the life data obtained from this empirical method is difficult to do inferences about reliability. This paper presents an accelerated destructive degradation test using thermal stress to obtain degradation data directly relates reliability to critical performance characteristic, which is the tensile strength in the intravascular catheter tip considered as a critical concern in patients’ safety. The degradation data model is given by a stochastic Wiener process with the drift parameter being represented as Arrhenius function. The parameters of the Wiener process and Arrhenius function are estimated using maximum likelihood; these parameters are used to estimate the first-passage time (time to failure) distribution when the intravascular catheters degradation path reaches a tensile strength critical value in each thermal stress level. Based on this, a complete product reliability assessment is performed and presented.es_MX
dc.description.urihttp://www.rmib.mx/index.php/rmib/article/view/1238es_MX
dc.language.isoen_USes_MX
dc.relation.ispartofProducto de investigación IITes_MX
dc.relation.ispartofInstituto de Ingeniería y Tecnologíaes_MX
dc.subjectDegradaciónes_MX
dc.subjectCatéteres_MX
dc.subjectProceso Wieneres_MX
dc.subject.otherinfo:eu-repo/classification/cti/7es_MX
dc.titleStudying the Effect of Temperature on the Tensile Strength of an Intravascular Catheter Using a Degradation Modeles_MX
dc.typeArtículoes_MX
dcterms.thumbnailhttp://ri.uacj.mx/vufind/thumbnails/rupiiit.pnges_MX
dcrupi.institutoInstituto de Ingeniería y Tecnologíaes_MX
dcrupi.cosechableSies_MX
dcrupi.norevista2es_MX
dcrupi.volumen43es_MX
dcrupi.nopagina24-38es_MX
dc.identifier.doi10.17488/RMIB.43.2.2es_MX
dc.contributor.coauthorMéndez-González, Luis Carlos
dc.contributor.coauthorRomero Lopez, Roberto
dc.contributor.coauthorRodriguez Picon, Luis Alberto
dc.journal.titleRevista Mexicana de Ingeniería Biomédicaes_MX
dc.contributor.authorexternoEsqueda Hernández, Kimberly
dc.contributor.alumnoprincipal183073es_MX
dcrupi.pronacesNingunoes_MX


Archivos en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem


Av. Plutarco Elías Calles #1210 • Fovissste Chamizal
Ciudad Juárez, Chihuahua, México • C.P. 32310 • Tel. (+52) 688 – 2100 al 09