dc.description.abstractFoot impedance plethysmography was implemented using two types of electrodes (dry and capacitive) and sole force sensors. The latter are commonly used for assessing diabetic foot ulcers (DFU). For impedance plethysmography, a tetrapolar configuration has been used with three different plantar setups: four skin contact electrodes, four capacitive contact electrodes and two Force Sensing Resistors (FSRs). In this work, FSRs have been considered as possible capacitive electrodes because the top substrate contains interdigitating conductive electrodes and a semiconductive polymer. All the measurements have been performed using a 1 mA/10 kHz excitation current and have been tried under the feet of a standing person to detect impedance plethysmography signals. Contact electrodes allow a good cardiac pulse signal while capacitive contact through the socks features mains interferences. Force sensing resistors with their forcedependent resistance in parallel to the capacitive coupling, were not able to detect cardiac pulse. But promising results can be anticipated from these findings provided higher frequencies are used and larger sensor areas to help detect altered skin states in diabetic footes_MX
dc.language.isoenes_MX
dc.publisherIOP Publishinges_MX
dc.relation.ispartofProducto de investigación IITes_MX
dc.relation.ispartofInstituto de Ingeniería y Tecnologíaes_MX
dc.rightsAtribución-NoComercial-SinDerivadas 2.5 México*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/2.5/mx/*
dc.subject.otherinfo:eu-repo/classification/cti/7es_MX
dc.titleBioimpedance plethysmography with capacitive electrodes and sole force sensors: comparative triales_MX
dc.typeMemoria in extensoes_MX
dcterms.thumbnailhttp://ri.uacj.mx/vufind/thumbnails/rupiiit.pnges_MX
dcrupi.institutoInstituto de Ingeniería y Tecnologíaes_MX
dcrupi.cosechableSies_MX
dcrupi.subtipoInvestigaciónes_MX
dcrupi.alcanceInternacionales_MX
dcrupi.paisMéxicoes_MX
dc.contributor.coauthorGonzalez Landaeta, Rafael Eliecer
dcrupi.tipoeventoCongresoes_MX
dcrupi.evento4th Latin American Conference on Bioimpedance 2021es_MX
dcrupi.estadoSan Luis Potosíes_MX
dc.contributor.authorexternoIsabel, Morales
dc.contributor.coauthorexternoSimini, Franco
dcrupi.colaboracionextUruguayes_MX
dcrupi.pronacesSaludes_MX


Archivos en el ítem

Thumbnail
Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Atribución-NoComercial-SinDerivadas 2.5 México
Excepto si se señala otra cosa, la licencia del ítem se describe como Atribución-NoComercial-SinDerivadas 2.5 México

Av. Plutarco Elías Calles #1210 • Fovissste Chamizal
Ciudad Juárez, Chihuahua, México • C.P. 32310 • Tel. (+52) 688 – 2100 al 09