Mostrar el registro sencillo del ítem
Bioimpedance plethysmography with capacitive electrodes and sole force sensors: comparative trial
dc.date.accessioned | 2021-11-19T17:43:42Z | |
dc.date.available | 2021-11-19T17:43:42Z | |
dc.date.issued | 2021-11-15 | es_MX |
dc.identifier.uri | http://cathi.uacj.mx/20.500.11961/19095 | |
dc.description.abstract | Foot impedance plethysmography was implemented using two types of electrodes (dry and capacitive) and sole force sensors. The latter are commonly used for assessing diabetic foot ulcers (DFU). For impedance plethysmography, a tetrapolar configuration has been used with three different plantar setups: four skin contact electrodes, four capacitive contact electrodes and two Force Sensing Resistors (FSRs). In this work, FSRs have been considered as possible capacitive electrodes because the top substrate contains interdigitating conductive electrodes and a semiconductive polymer. All the measurements have been performed using a 1 mA/10 kHz excitation current and have been tried under the feet of a standing person to detect impedance plethysmography signals. Contact electrodes allow a good cardiac pulse signal while capacitive contact through the socks features mains interferences. Force sensing resistors with their forcedependent resistance in parallel to the capacitive coupling, were not able to detect cardiac pulse. But promising results can be anticipated from these findings provided higher frequencies are used and larger sensor areas to help detect altered skin states in diabetic foot | es_MX |
dc.language.iso | en | es_MX |
dc.publisher | IOP Publishing | es_MX |
dc.relation.ispartof | Producto de investigación IIT | es_MX |
dc.relation.ispartof | Instituto de Ingeniería y Tecnología | es_MX |
dc.rights | Atribución-NoComercial-SinDerivadas 2.5 México | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/2.5/mx/ | * |
dc.subject.other | info:eu-repo/classification/cti/7 | es_MX |
dc.title | Bioimpedance plethysmography with capacitive electrodes and sole force sensors: comparative trial | es_MX |
dc.type | Memoria in extenso | es_MX |
dcterms.thumbnail | http://ri.uacj.mx/vufind/thumbnails/rupiiit.png | es_MX |
dcrupi.instituto | Instituto de Ingeniería y Tecnología | es_MX |
dcrupi.cosechable | Si | es_MX |
dcrupi.subtipo | Investigación | es_MX |
dcrupi.alcance | Internacional | es_MX |
dcrupi.pais | México | es_MX |
dc.contributor.coauthor | Gonzalez Landaeta, Rafael Eliecer | |
dcrupi.tipoevento | Congreso | es_MX |
dcrupi.evento | 4th Latin American Conference on Bioimpedance 2021 | es_MX |
dcrupi.estado | San Luis Potosí | es_MX |
dc.contributor.authorexterno | Isabel, Morales | |
dc.contributor.coauthorexterno | Simini, Franco | |
dcrupi.colaboracionext | Uruguay | es_MX |
dcrupi.pronaces | Salud | es_MX |
Archivos en el ítem
Este ítem aparece en la(s) siguiente(s) colección(ones)
-
Memoria en extenso [270]