Mostrar el registro sencillo del ítem

dc.contributor.authorBravo Martinez, Gabriel
dc.date.accessioned2021-11-19T17:32:05Z
dc.date.available2021-11-19T17:32:05Z
dc.date.issued2021-11-13es_MX
dc.identifier.urihttp://cathi.uacj.mx/20.500.11961/19088
dc.description.abstractHeart rate (HR) is an essential indicator of health in the human body. It measures the number of times per minute that the heart contracts or beats. An irregular heartbeat can signify a severe health condition, so monitoring heart rate periodically can help prevent heart complications. This paper presents a novel wearable sensing approach for remote HR measurement by a compact resistance-to-microcontroller interface circuit. A heartbeat’s signal can be detected by a Force Sensing Resistor (FSR) attached to the body near large arteries (such as the carotid or radial), which expand their area each time the heart expels blood to the body. Depending on how the sensor interfaces with the subject, the FSR changes its electrical resistance every time a pulse is detected. By placing the FSR in a direct interface circuit, those resistance variations can be measured directly by a microcontroller without using either analog processing stages or an analog-to-digital converter. In this kind of interface, the self-heating of the sensor is avoided, since the FSR does not require any voltage or bias current. The proposed system has a sampling rate of 50 Sa/s, and an effective resolution of 10 bits (200 mΩ), enough for obtaining well-shaped cardiac signals and heart rate estimations in real time by the microcontroller. With this approach, the implementation of wearable systems in health monitoring applications is more feasiblees_MX
dc.description.urihttps://www.mdpi.com/1424-8220/21/22/7549/htmes_MX
dc.description.urihttps://www.mdpi.com/1424-8220/21/22/7549/pdfes_MX
dc.language.isoen_USes_MX
dc.relation.ispartofProducto de investigación IITes_MX
dc.relation.ispartofInstituto de Ingeniería y Tecnologíaes_MX
dc.subjectwearable health monitoringes_MX
dc.subjectresistance-to-time interface circuites_MX
dc.subjectforce-sensing resistores_MX
dc.subject.otherinfo:eu-repo/classification/cti/7es_MX
dc.titleA Power-Efficient Sensing Approach for Pulse Wave Palpation-Based Heart Rate Measurementes_MX
dc.typeArtículoes_MX
dcterms.thumbnailhttp://ri.uacj.mx/vufind/thumbnails/rupiiit.pnges_MX
dcrupi.institutoInstituto de Ingeniería y Tecnologíaes_MX
dcrupi.cosechableSies_MX
dcrupi.norevista22es_MX
dcrupi.volumen21es_MX
dcrupi.nopagina1-14es_MX
dc.identifier.doihttps://doi.org/10.3390/s21227549es_MX
dc.contributor.coauthorSilva Aceves, Jesus Martin
dc.contributor.coauthorNoriega, Salvador
dc.contributor.coauthorMartinez Gomez, Erwin Adan
dc.contributor.coauthorEnriquez Aguilera, Francisco Javier
dc.contributor.coauthorSifuentes de la Hoya, Ernesto
dc.journal.titleSensorses_MX
dcrupi.pronacesSaludes_MX


Archivos en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem


Av. Plutarco Elías Calles #1210 • Fovissste Chamizal
Ciudad Juárez, Chihuahua, México • C.P. 32310 • Tel. (+52) 688 – 2100 al 09