Mostrar el registro sencillo del ítem

dc.date.accessioned2021-08-05T19:07:44Z
dc.date.available2021-08-05T19:07:44Z
dc.date.issued2021-06-25es_MX
dc.identifier.isbn978-0-7381-3135-1
dc.identifier.urihttp://cathi.uacj.mx/20.500.11961/18669
dc.description.abstractDiabetic Foot Ulcers are ominous consequence of Diabetic Foot. Only general preventive guidelines are available, and ulcers happen with no previous notice. To develop a multidimensional ulcer opening warning device: temperature, pressure, humidity and friction are usually considered. We use standard flexible Force Sensing Resistors FSR 402 to detect not only plantar pressure, but also plantar bioimpedance. Since FSR includes conductive electrodes covered by polymer films, the interface with the subject can be considered a capacitive electrode. A special bioimpedance detection circuit is required to inject current using two homologous FSR 402 contacts and measuring the resulting voltage from the other two contacts available. This circuit is able to detect the cardiac activity from the foot sole. For the first time, pressure sensors are used as bioimpedance electrodes.es_MX
dc.language.isoenes_MX
dc.publisherIEEEes_MX
dc.relation.ispartofProducto de investigación IITes_MX
dc.relation.ispartofInstituto de Ingeniería y Tecnologíaes_MX
dc.rightsAtribución-NoComercial-SinDerivadas 2.5 México*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/2.5/mx/*
dc.subjectdiabetic foot ulceres_MX
dc.subjectpressure sensores_MX
dc.subjectbioimpedancees_MX
dc.subjectimpedance plethysmographyes_MX
dc.subjectplantar electrodeses_MX
dc.subjectwearable devicees_MX
dc.subject.otherinfo:eu-repo/classification/cti/7es_MX
dc.titlePressure sensors used as bioimpedance plantar electrodes: a feasibility studyes_MX
dc.typeMemoria in extensoes_MX
dcterms.thumbnailhttp://ri.uacj.mx/vufind/thumbnails/rupiiit.pnges_MX
dcrupi.institutoInstituto de Ingeniería y Tecnologíaes_MX
dcrupi.cosechableSies_MX
dcrupi.subtipoInvestigaciónes_MX
dcrupi.alcanceInternacionales_MX
dcrupi.paisSuizaes_MX
dc.contributor.coauthorGonzalez Landaeta, Rafael Eliecer
dcrupi.tipoeventoCongresoes_MX
dcrupi.evento2021 IEEE International Symposium on Medical Measurements and Applicationses_MX
dc.lgacSin línea de generaciónes_MX
dc.cuerpoacademicoSin cuerpo académicoes_MX
dc.contributor.authorexternoMorales, Isabel
dc.contributor.coauthorexternoSimini, Franco
dcrupi.colaboracionextUruguayes_MX


Archivos en el ítem

Thumbnail
Thumbnail
Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Atribución-NoComercial-SinDerivadas 2.5 México
Excepto si se señala otra cosa, la licencia del ítem se describe como Atribución-NoComercial-SinDerivadas 2.5 México

Av. Plutarco Elías Calles #1210 • Fovissste Chamizal
Ciudad Juárez, Chihuahua, México • C.P. 32310 • Tel. (+52) 688 – 2100 al 09