Mostrar el registro sencillo del ítem

dc.contributor.authorMota, Maria de la Luz
dc.date.accessioned2021-06-03T19:30:33Z
dc.date.available2021-06-03T19:30:33Z
dc.date.issued2021-02-25es_MX
dc.identifier.urihttp://cathi.uacj.mx/20.500.11961/18443
dc.description.abstractThe diagnosis of diseases based on immunosensors have been objective of research in the last years, providing an improvement for a rapid detection, high sensitivity, precision, accuracy, specificity and resolution. Areas of progress such as analytical technologies, interpretation and standardization has been done for common biomarkers. However, years of research and development of a functional immunosensor with an unusual biomarker require further investigation to be optimized in any aspect. Recent development of biosensors to diagnose nervous system diseases, such as immunosensors for multiple sclerosis, has been the object of study in the past 10 years to improve common in vitro diagnostic methods such as enzyme-linked immunosorbent assays (ELISA) on cerebrospinal fluid (CSF), showing a big opportunity for further diagnostic optimization. The aim of this review is to show a report on the development of in vitro immunosensors for multiple sclerosis diagnosis until today, with the particular focus on monitoring analyte concentration levels on cerebrospinal fluid and serum as a contribution and improvement to current diagnostic methods.es_MX
dc.description.urihttps://link.springer.com/article/10.1007/s13206-021-00018-zes_MX
dc.language.isoen_USes_MX
dc.relation.ispartofProducto de investigación IITes_MX
dc.relation.ispartofInstituto de Ingeniería y Tecnologíaes_MX
dc.rightsAtribución-NoComercial-SinDerivadas 2.5 México*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/2.5/mx/*
dc.subjectMultiple sclerosis · Myelin basic protein · Immunosensors · Nanotechnology · Diagnostic methods · Biomarkerses_MX
dc.subject.otherinfo:eu-repo/classification/cti/7es_MX
dc.titleAdvances for the Development of In Vitro Immunosensors for Multiple Sclerosis Diagnosises_MX
dc.typeArtículoes_MX
dcterms.thumbnailhttp://ri.uacj.mx/vufind/thumbnails/rupiiit.pnges_MX
dcrupi.institutoInstituto de Ingeniería y Tecnologíaes_MX
dcrupi.cosechableSies_MX
dc.identifier.doihttps://doi.org/10.1007/s13206-021-00018-zes_MX
dc.contributor.coauthorCarrillo, Amanda
dc.journal.titleBioChip Journales_MX
dc.lgacSin línea de generaciónes_MX
dc.cuerpoacademicoSin cuerpo académicoes_MX
dc.contributor.coauthorexternoAguirre Tostado, Francisco S.
dc.contributor.coauthorexternoGuerrero Villalba, Jorge M.


Archivos en el ítem

Thumbnail
Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Atribución-NoComercial-SinDerivadas 2.5 México
Excepto si se señala otra cosa, la licencia del ítem se describe como Atribución-NoComercial-SinDerivadas 2.5 México

Av. Plutarco Elías Calles #1210 • Fovissste Chamizal
Ciudad Juárez, Chihuahua, México • C.P. 32310 • Tel. (+52) 688 – 2100 al 09