Mostrar el registro sencillo del ítem

dc.contributor.authorSevereyn, Erika
dc.date.accessioned2019-11-22T20:06:33Z
dc.date.available2019-11-22T20:06:33Z
dc.date.issued2019-10-05
dc.identifier.isbn978-3-030-30648-9es_MX
dc.identifier.urihttp://cathi.uacj.mx/20.500.11961/8651
dc.description.abstractImpaired glucose tolerance (IGT), impaired fasting glucose (IFG) and insulin resistance (IR) are prediabetic conditions diagnosed by glucose and insulin values measured by oral glucose tolerance test (OGTT). In the OGTT, insulin and glucose levels are measured in five different blood samples: a sample in fasting (minute 0) and four others after oral intake of 75 gr of glucose, at intervals of 30 min (minute 30, 60, 90, and 120). The values of glucose at 0 and 120 min from OGTT are used for the diagnosis of IFG and IGT, respectively. The HOMA-IR is the most used method of determining IR in large populationbased studies; it is mathematically derived from fasting glucose and insulin measurements from OGTT. One of the limitations of HOMA-IR is the difficulty of predicting IR in populations with IGT. The aim of this study is to evaluate the capability of a HOMA-IR and modified version of HOMA-IR (HOMA-IR calculated from glucose and insulin of 30, 60, 90 and 120 min of OGTT) to diagnose IGT, IR, and IFG. Receiver operating characteristic (ROC) curves and area under the ROC curve (AUC) were performed to assess the predictive capacity of HOMA-IR and modified versions. The present study demonstrated that modified versions of HOMA-IR calculated using glucose and insulin from 60 and 90 min of OGTT are alternative indexes (AUC < 0.70) for IGT, IFG and IR detection.es_MX
dc.description.urihttps://www.springer.com/series/7403es_MX
dc.language.isoenes_MX
dc.publisherSpringer Naturees_MX
dc.relation.ispartofProducto de investigación IITes_MX
dc.relation.ispartofInstituto de Ingeniería y Tecnologíaes_MX
dc.subjectHOMA-IRes_MX
dc.subjectROC - curveses_MX
dc.subjectImpaired glucose tolerancees_MX
dc.subjectImpaired fasting glucosees_MX
dc.subjectInsulin resistancees_MX
dc.subject.otherinfo:eu-repo/classification/cti/3es_MX
dc.titleHOMA-IR Assessment for Impaired Glucose Tolerance, Impaired Fasting Glucose and Insulin Resistance Diagnosises_MX
dc.typeCapítulo de libroes_MX
dcterms.thumbnailhttp://ri.uacj.mx/vufind/thumbnails/rupiiit.pnges_MX
dcrupi.institutoInstituto de Ingeniería y Tecnologíaes_MX
dcrupi.cosechableSies_MX
dcrupi.subtipoInvestigaciónes_MX
dcrupi.nopagina1275-1283es_MX
dcrupi.alcanceInternacionales_MX
dcrupi.paisMéxicoes_MX
dc.identifier.doihttps://doi.org/10.1007/978-3-030-30648-9_164es_MX
dc.contributor.coauthorVelásquez, Jesús
dc.contributor.coauthorPerpiñan, Gilberto
dc.contributor.coauthorHerrera, Héctor
dc.contributor.coauthorWong, Sara
dc.contributor.coauthorDiaz Roman, Jose David
dc.contributor.coauthorAltuve, Miguel
dcrupi.estadoQuintana Rooes_MX
dc.lgacProcesamiento de Imágenes Biomédicas y Bioinformáticaes_MX
dc.cuerpoacademicoEstudios en Sistemas Digitaleses_MX
dcrupi.titulolibroIFMBE Proceedings. VIII Latin American Conference on Biomedical Engineering and XLII National Conference on Biomedical Engineeringes_MX


Archivos en el ítem

Thumbnail
Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem


Av. Plutarco Elías Calles #1210 • Fovissste Chamizal
Ciudad Juárez, Chihuahua, México • C.P. 32310 • Tel. (+52) 688 – 2100 al 09