Mostrar el registro sencillo del ítem

dc.contributor.authorGallegos-Aguilar, Ana Cristina Gallegos-Aguilar
dc.date.accessioned2019-06-17T19:07:26Z
dc.date.available2019-06-17T19:07:26Z
dc.date.issued2019-02-01
dc.identifier.urihttp://cathi.uacj.mx/20.500.11961/7868
dc.description.abstractAbstract To monitor and detect blood glucose (BG) abnormalities, health professionals use glucose meters. The study’s objective was to compare HemoCue (HC) versus glucose oxidase (GOx) for the measurement of BG using 368 measurements of BG by both methods. Bland & Altman graphs, paired t-test and linear regression were used to compare the methods. Concordance was found between the methods in most glucose levels, except at glucose concentrations ≥ 6.993 mmol / L. HC glucose analyzer is good for use in field studies because it is technically easy and requires very little maintenance; however, it is recommended to take special care with people whose glucose values are within the limit of the diagnosis of diabetes, since with the HC method there is a risk of misclassifying people who already have diabetes, as non-diabetics. Therefore, given the importance of knowing the actual values of glucose levels in this group of people for an accurate diagnosis, considering a subsequent analysis with the GOx method to corroborate the result is recommended.es_MX
dc.description.urihttps://biotecnia.unison.mx/index.php/biotecnia/article/view/809es_MX
dc.language.isoenes_MX
dc.relation.ispartofProducto de investigación ICBes_MX
dc.relation.ispartofInstituto de Ciencias Biomédicases_MX
dc.rightsAtribución-NoComercial-SinDerivadas 2.5 México*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/2.5/mx/*
dc.subjectBlood glucosees_MX
dc.subjectHemoCuees_MX
dc.subjectGlucose Oxidasees_MX
dc.subject.otherinfo:eu-repo/classification/cti/3es_MX
dc.titleAgreement between hemocue and glucose oxidase methods for blood glucose measurement in a field work study of diabetes: the Comcaac projectes_MX
dc.title.alternativeConcordancia entre hemocue y glucosa oxidasa en el análisis de la concentración de glucosa sanguínea en un estudio de diabetes: el proyecto Comcáaces_MX
dc.typeArtículoes_MX
dcterms.thumbnailhttp://ri.uacj.mx/vufind/thumbnails/rupiicb.pnges_MX
dcrupi.institutoInstituto de Ciencias Biomédicases_MX
dcrupi.cosechableSies_MX
dcrupi.norevista21es_MX
dcrupi.volumen1es_MX
dcrupi.nopagina22-28es_MX
dc.contributor.coauthorEsparza-Romero, Julian
dc.contributor.coauthorHernández Martínez, Héctor Hiram
dc.contributor.coauthorUrquidez Romero, Rene
dc.contributor.coauthorQuizán-Plata, Trinidad
dc.contributor.coauthorRascón Careaga, Antonio
dc.contributor.coauthorBolado Martínez, Enrique
dc.contributor.coauthorDíaz Zavala, Rolando Giovanni
dc.journal.titleBiotecniaes_MX
dc.lgacIntervención Nutricional y de Actividad Física para Prevención de Enfermedades Crónico-Degenerativases_MX
dc.cuerpoacademicoSalud Comunitariaes_MX


Archivos en el ítem

Thumbnail
Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Atribución-NoComercial-SinDerivadas 2.5 México
Excepto si se señala otra cosa, la licencia del ítem se describe como Atribución-NoComercial-SinDerivadas 2.5 México

Av. Plutarco Elías Calles #1210 • Fovissste Chamizal
Ciudad Juárez, Chihuahua, México • C.P. 32310 • Tel. (+52) 688 – 2100 al 09