Mostrar el registro sencillo del ítem
Plethysmographic and anthropometric validation of a 3D body image digitizer to determine body dimensions
dc.contributor.author | Ramos-Jimenez, Arnulfo | |
dc.date.accessioned | 2018-11-29T20:55:49Z | |
dc.date.available | 2018-11-29T20:55:49Z | |
dc.date.issued | 2018-04-02 | |
dc.identifier.uri | http://cathi.uacj.mx/20.500.11961/4223 | |
dc.description.abstract | Image digitizing has facilitated body shape evaluation gained entry in ergonomics industry, in fashion and in health. Objective: to validate the 3D image digitizer (TC2-18) to determine body dimensions in a fast and reliable manner. Methods: 285 adults of both sexes were studied to measure anthropometrics, plethysmography, and digitized body shape. Results: Digitizer obtained measurements highly correlated with those obtained through anthropometrics and plethysmography (R2 ≥ 0.75). However, the TC2-18 gave lower values in total body volume when compared with plethysmography (CI 95%, −3.9 to −3.5 L). In contrast, the TC2-18 yielded higher values in mesosternal (CI 95%, 8.8–9.6 cm), neck (CI 95%, 2.6–3.0 cm), gluteus maximus (CI 95%, 3.1–3.7 cm), relaxed arm (CI 95%, 2.9–3.3 cm), and minimal waist (CI 95%, 3.1–3.7 cm) circumferences; as well as similar data for the upper thigh, calf and forearm circumference. Conclusion: TC2-18 3D digitizer yielded valid and reliable measures when adult persons are evaluated. Found differences occur due to movement during digitizing and by difference inherent to the used devices. | es_MX |
dc.description.uri | https://www.sciencedirect.com/science/article/abs/pii/S0169814117304353 | es_MX |
dc.language.iso | en | es_MX |
dc.relation.ispartof | Producto de investigación ICB | es_MX |
dc.relation.ispartof | Instituto de Ciencias Biomédicas | es_MX |
dc.subject | 3D body image digitizer | es_MX |
dc.subject | Ergonomics | es_MX |
dc.subject | Somatotype | es_MX |
dc.subject | Plethysmography | es_MX |
dc.subject | Anthropometry | es_MX |
dc.subject | Densitometry | es_MX |
dc.subject.lcc | Research Subject Categories::MEDICINE::Morphology, cell biology, pathology::Morphology | es_MX |
dc.title | Plethysmographic and anthropometric validation of a 3D body image digitizer to determine body dimensions | es_MX |
dc.type | Artículo | es_MX |
dcterms.thumbnail | http://ri.uacj.mx/vufind/thumbnails/rupiicb.png | es_MX |
dcrupi.instituto | Instituto de Ciencias Biomédicas | es_MX |
dcrupi.cosechable | Si | es_MX |
dcrupi.norevista | 67 | es_MX |
dcrupi.nopagina | 1-5 | es_MX |
dc.identifier.doi | 10.1016/j.ergon.2018.04.006 | es_MX |
dc.contributor.coauthor | Hernández-Torres, Rosa Patricia | |
dc.contributor.coauthor | Villalobos-Molina, Rafael | |
dc.contributor.coauthor | URQUIDEZ ROMERO, RENE | |
dc.journal.title | International Journal of Industrial Ergonomics | es_MX |
dc.lgac | Fisiología y Bioquímica de la Actividad Física, Deporte y Salud Preventiva | es_MX |
dc.cuerpoacademico | Salud Comunitaria | es_MX |