Mostrar el registro sencillo del ítem
Plethysmographic and anthropometric validation of a 3D body image digitizer to determine body dimensions
dc.contributor.author | Ramos-Jiménez, Arnulfo | |
dc.date.accessioned | 2018-11-28T21:10:06Z | |
dc.date.available | 2018-11-28T21:10:06Z | |
dc.date.issued | 2018-05-01 | |
dc.identifier.uri | http://cathi.uacj.mx/20.500.11961/4116 | |
dc.description.abstract | Abstract Image digitizing has facilitated body shape evaluation gained entry in ergonomics industry, in fashion and in health. Objective: to validate the 3D image digitizer (TC2-18) to determine body dimensions in a fast and reliable manner. Methods: 285 adults of both sexes were studied to measure anthropometrics, plethysmography, and digitized body shape. Results: Digitizer obtained measurements highly correlated with those obtained through anthropometrics and plethysmography (R2≥0.75). However, the TC2-18 gave lower values in total body volume when compared with plethysmography (CI 95%, −3.9 to −3.5 L). In contrast, the TC2-18 yielded higher values in mesosternal (CI 95%, 8.8–9.6 cm), neck (CI 95%, 2.6–3.0 cm), gluteus maximus (CI 95%, 3.1–3.7 cm), relaxed arm (CI 95%, 2.9–3.3 cm), and minimal waist (CI 95%, 3.1–3.7 cm) circumferences; as well as similar data for the upper thigh, calf and forearm circumference. Conclusion: TC2-18 3D digitizer yielded valid and reliable measures when adult persons are evaluated. Found differences occur due to movement during digitizing and by difference inherent to the used devices. | es_MX |
dc.description.uri | https://reader.elsevier.com/reader/sd/pii/S0169814117304353?token=CD89ED7CF264B4964B11DD437E60D8F092E4CF63C22D9EC2E03DD0881BD225CBFE40A5993F265101A724A6A5B76DC5CC | es_MX |
dc.language.iso | en_US | es_MX |
dc.relation.ispartof | Producto de investigación ICB | es_MX |
dc.relation.ispartof | Instituto de Ciencias Biomédicas | es_MX |
dc.rights | Atribución-NoComercial-SinDerivadas 2.5 México | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/2.5/mx/ | * |
dc.subject | 3D body image digitizer | es_MX |
dc.subject | Ergonomics | es_MX |
dc.subject | Somatotype | es_MX |
dc.subject | Plethysmography | es_MX |
dc.subject | Anthropometry | es_MX |
dc.subject | Densitometry | es_MX |
dc.subject.other | info:eu-repo/classification/cti/3 | es_MX |
dc.title | Plethysmographic and anthropometric validation of a 3D body image digitizer to determine body dimensions | es_MX |
dc.type | Artículo | es_MX |
dcterms.thumbnail | http://ri.uacj.mx/vufind/thumbnails/rupiicb.png | es_MX |
dcrupi.instituto | Instituto de Ciencias Biomédicas | es_MX |
dcrupi.cosechable | Si | es_MX |
dcrupi.subtipo | Investigación | es_MX |
dcrupi.volumen | 67 | es_MX |
dcrupi.nopagina | 1-5 | es_MX |
dcrupi.alcance | Nacional | es_MX |
dcrupi.pais | México | es_MX |
dc.identifier.doi | https://doi.org/10.1016/j.ergon.2018.04.006 | es_MX |
dc.contributor.coauthor | Hernández-Torres, Rosa P | |
dc.contributor.coauthor | Villalobos-Molina, Rafael | |
dc.contributor.coauthor | URQUIDEZ ROMERO, RENE | |
dc.journal.title | International Journal of Industrial Ergonomics | es_MX |
dc.lgac | Intervención Nutricional y de Actividad Física para Prevención de Enfermedades Crónico-Degenerativas | es_MX |
dc.cuerpoacademico | Salud Comunitaria | es_MX |