Mostrar el registro sencillo del ítem
Lithium Niobate Perovskite as the Support for Silver Nanoparticles for Non-Enzymatic Electrochemical Detection of Glucose
dc.date.accessioned | 2024-10-18T17:54:57Z | |
dc.date.available | 2024-10-18T17:54:57Z | |
dc.date.issued | 2024-10-15 | es_MX |
dc.identifier.uri | https://cathi.uacj.mx/20.500.11961/28887 | |
dc.description.abstract | : Lithium niobate perovskite and silver nanoparticle-based nanocomposites (LNB:AgNPs) were explored for developing an electrochemical glucose sensor. The perovskite to silver nanoparticle ratios investigated were 4:1, 1:1, 1:2, 2:1, and 1:4. Among these, the 4:1 ratio, with the lowest silver content, demonstrated the most stable performance during glucose quantification via amperometry. The sensor’s response was evaluated measuring the current at a fixed potential of 0.7 V following the injection of 1 mM glucose with each addition. The calibration curve obtained from the recorded data exhibited a linear response within the 1 to 15 mM glucose concentration range, achieving a sensitivity of 2 µA/mM, a high correlation coefficient (R2 = 0.997), and a limit of detection (LOD) of 0.5 µM. The LNB4:1AgNP composite allowed taking advantage of the unique properties of both components in a balanced manner, maximizing the sensor performance in practical applications. | es_MX |
dc.description.uri | https://www.mdpi.com/2227-9040/12/10/210 | es_MX |
dc.language.iso | en_US | es_MX |
dc.relation.ispartof | Producto de investigación ICB | es_MX |
dc.relation.ispartof | Instituto de Ciencias Biomédicas | es_MX |
dc.subject | electrochemical sensor; glucose; homemade electrode; lithium niobate; perovskite; silver nanoparticles | es_MX |
dc.subject.other | info:eu-repo/classification/cti/3 | es_MX |
dc.title | Lithium Niobate Perovskite as the Support for Silver Nanoparticles for Non-Enzymatic Electrochemical Detection of Glucose | es_MX |
dc.type | Artículo | es_MX |
dcterms.thumbnail | http://ri.uacj.mx/vufind/thumbnails/rupiicb.png | es_MX |
dcrupi.instituto | Instituto de Ciencias Biomédicas | es_MX |
dcrupi.cosechable | Si | es_MX |
dcrupi.norevista | 12 | es_MX |
dcrupi.volumen | 210 | es_MX |
dcrupi.nopagina | 1-16 | es_MX |
dc.identifier.doi | https://doi.org/10.3390/chemosensors12100210 | es_MX |
dc.contributor.coauthor | Reyes-López, Simón Yobanny | |
dc.contributor.coauthor | Espinosa Cristobal, Leon Francisco | |
dc.journal.title | Chemosensors | es_MX |
dc.contributor.authorexterno | Piñon-Balderrama, Claudia Ivone | |
dc.contributor.coauthorexterno | Manriquez-Tristan, Atenea | |
dc.contributor.coauthorexterno | Maldonado-Orozco, Maria Cristina | |
dc.contributor.coauthorexterno | Hernandez-Escobar, Claudia Alejandra | |
dc.contributor.coauthorexterno | Zaragoza Contreras, Erasto Armando | |
dc.contributor.coauthorexterno | Zaragoza Contreras, Erasto Armando | |
dcrupi.pronaces | Salud | es_MX |