Mostrar el registro sencillo del ítem

dc.contributor.authorReyes-López, Simón Yobanny
dc.date.accessioned2024-01-18T01:46:59Z
dc.date.available2024-01-18T01:46:59Z
dc.date.issued2023-09-15es_MX
dc.identifier.urihttp://cathi.uacj.mx/20.500.11961/28182
dc.description.abstractThe importance of biomarker quantification in technology cannot be overstated. It has numerous applications in medical diagnostics, drug delivery, and the timely implementation of prevention and control strategies for highly prevalent diseases worldwide. However, the discovery of new tools for detection has become increasingly necessary. One promising avenue is the use of perovskite-based materials, which exhibit excellent catalytic activity and redox properties. These make them ideal candidates for the development of electrochemical sensors. In this review, the advances of purely non-enzymatic electrochemical detection of bio-analytes, with ABO3 perovskite form, are presented. The work allows the visualization of some of the modifications in the composition and crystal lattice of the perovskites and some variations in the assembly of the electrodes, which can result in systems with a better response to the detection of analytes of interest. These findings have significant implications for improving the accuracy and speed of biomarker detection, ultimately benefiting patients and healthcare professionals alike.es_MX
dc.description.urihttps://www.mdpi.com/2227-9040/11/9/507es_MX
dc.language.isospaes_MX
dc.relation.ispartofProducto de investigación ICBes_MX
dc.relation.ispartofInstituto de Ciencias Biomédicases_MX
dc.rightsAtribución-NoComercial-SinDerivadas 2.5 México*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/2.5/mx/*
dc.subjectnon-enzymatic; electrochemical; perovskite-based sensor; human health biomarkers; glucose; hydrogen peroxide; urea; uric acides_MX
dc.subject.otherinfo:eu-repo/classification/cti/2es_MX
dc.titleElectrochemical Perovskite-Based Sensors for the Detection of Relevant Biomarkers for Human Kidney Healthes_MX
dc.typeArtículoes_MX
dcterms.thumbnailhttp://ri.uacj.mx/vufind/thumbnails/rupiicb.pnges_MX
dcrupi.institutoInstituto de Ciencias Biomédicases_MX
dcrupi.cosechableSies_MX
dcrupi.norevista1es_MX
dcrupi.volumen11es_MX
dcrupi.nopagina1-21es_MX
dc.identifier.doihttps://doi.org/10.3390/chemosensors11090507es_MX
dc.journal.titleChemosensorses_MX
dc.contributor.coauthorexternoZaragoza-Contreras, Erasto Armando
dc.contributor.coauthorexternoMaldonado-Orozco, María Cristina
dc.contributor.coauthorexternoEstrada-Monje, Anayansi
dc.contributor.coauthorexternoConejo-Dávila, Alain Salvador
dc.contributor.coauthorexternoLeyva-Porras, César
dc.contributor.coauthorexternoPiñón-Balderrama, Claudia Ivone
dcrupi.impactosocialsies_MX
dcrupi.vinculadoproyextnoes_MX
dcrupi.pronacesNingunoes_MX
dcrupi.vinculadoproyintnoes_MX


Archivos en el ítem

Thumbnail
Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Atribución-NoComercial-SinDerivadas 2.5 México
Excepto si se señala otra cosa, la licencia del ítem se describe como Atribución-NoComercial-SinDerivadas 2.5 México

Av. Plutarco Elías Calles #1210 • Fovissste Chamizal
Ciudad Juárez, Chihuahua, México • C.P. 32310 • Tel. (+52) 688 – 2100 al 09